Annicom Axio Logo  
    +44(0)1420487788  
 
home | about us | products | datasheets | account
 
   
datasheetdetails
 <<  |  <  |   AX-WM-HM67C - Heat Meter Integrator
Multival 601 Heat and Cool meter
AX-WM-HM67C-6-00-7-B / Multival 601 Heat and Cool meter, RTC + 66-C Compatibility + Pulse output, Data + pulse intputs, 230Vac supply , Pocket sensor set with 5m cable POA Qty
AX-WM-HM67C-6-20-7-B / Multival 601 Heat and Cool meter, RTC + 66-C Compatibility + Pulse output, M-Bus + pulse inputs, 230Vac supply , Pocket sensor set with 5m cable POA Qty
AX-WM-HM67C-6-24-7-B / Multival 601 Heat and Cool meter, RTC + 66-C Compatibility + Pulse output, LonWorks,FTT-10A + pulse inputs, 230Vac supply , Pocket sensor set with 5m cable POA Qty
AX-WM-HM67C-6-00-8-B / Multival 601 Heat and Cool meter, RTC + 66-C Compatibility + Pulse output, Data + pulse intputs, 24Vac supply, Pocket sensor set with 5m cable POA Qty
AX-WM-HM67C-6-20-8-B / Multival 601 Heat and Cool meter, RTC + 66-C Compatibility + Pulse output, M-Bus + pulse inputs, 24Vac supply, Pocket sensor set with 5m cable POA Qty
AX-WM-HM67C-6-24-8-B / Multival 601 Heat and Cool meter, RTC + 66-C Compatibility + Pulse output, LonWorks,FTT-10A + pulse inputs, 24Vac supply, Pocket sensor set with 5m cable POA Qty
 <<  |  <  | OVERVIEW | SPECIFICATION | DATASHEETS        

The AX-WM-HM67C is an exceptionally versatile meter with a wide range of features including data logging, PQ Limiter and leak detection. The unit has been designed for district heating or cooling systems and is an integrated intelligent unit. It can output the data using a variety of plug in modules such as Data/Pulse output to a BMS or M-bus, LON, Analogue or even a wireless option. The unit can be used in either closed or open systems and the unit can be used for both heating and cooling storing thedata in diferent registers which facilitates differentiated user rates. The unit comes with a pair of matched Pt500 sensors and a variety of power supply options.
Product Features
• Measures Heating and Cooling
• Nominal flow of 0.6 to 3000m3/hr
• two additional pulse input can be connected
• EN 1434, DS2340, OIML R75, PTB approved
• Battery Backup
• Data is logged for 15 years
• Power and flow limiter
• 230 or 24 Vac supply or 10 year battery

Power Supply
specify 230Vac, +/- 15-30% 48 to 52Hz

24Vac/Dc +/- 30%

D-Cell Lithium HiCap Battery (typically 10 years life)
Power Consumption
< 1 Watt
Display Type
8 + 3 digit LCD 7mm high
Datalogging
460 days, 36 months and 15 years
Nominal Flow Rate
Qn 0.6 to 3,000 m3/hr
Inputs
max 2 or 3 temperature inputs PT500 (to EN 60751)

1 or 2 flow meter inputs (pulse/litre)

A > 1 second duration

B > 0.15 second duration
Top plug in module
real time clock, CE + CV Outputs, PQ limiter 2 pulse inputs (add from electricity, water or gas meters )
Outputs
Galvanically insulated serial data output (can be converted to RS232)
Memory
EEPROM

option Pulse output, M-Bus , Analogue, LON-FTT-10, wireless

Pulse length = 32 ms , 30Vdc@10ma
Temperature Range
0 to 160 deg C
Differential Range
3K to 150K
Ambient Temperature
5 to 55 deg C
Protection
IP54
Conformity
EN 1434, DS2340, OIML R75, PTB approved

CE; LVD, EN 50 081-1 and EN 50 082-1
Dimensions
0.4 Kgs
Country of Origin
Denmark EU

AX-WM-HM67C.pdf / Heat Meter Integrator